Automotive Test Scope ATS610004D-XMSG

$2,756.18 (converted)

Key specifications

  • 14 bit (0.006 %) resolution (16 bit enhanced resolution)
  • Up to 1 GSa/s sampling
  • 250 MHz bandwidth
  • Up to 200 MSa/s continuous streaming
  • Up to 256 Mpoints memory per channel
  • 0.25 % DC vertical accuracy, 0.1 % typical
  • 1 ppm time base accuracy

In stock

SKU: ATS610004D-XMSG Category: Brand: GTIN-13 (EAN): 7423634563582

Description

The USB labscope packed with technology

This powerful USB 3.0 super speed automotive oscilloscope combines fast sampling up to 1 GSa/s with high resolutions of 12, 14 and 16 bit and a large memory of 64 Mpoints on all four channels. Additionally, the automotive oscilloscope supports continuous streaming measurements up to 200 MSa/s.

The Automotive Test Scope ATS610004D-XMSG is delivered with SureConnect connection test and resistance measurement on each channel.

Also, the Automotive Test Scope ATS610004D-XMSG is delivered with SafeGround. With SafeGround you can switch the differential inputs of the Automotive Test Scope ATS610004D-XMSG into single-ended inputs with ground protection. It allows to make measurements using standard attenuating probes and protects the scope when a short circuit to ground is created.

Safe measuring

Diff input

The Automotive Test Scope ATS610004D-XMSG is a four channel automotive oscilloscope with differential inputs. With the differential inputs it is possible to measure four totally unrelated signals simultaneously. It is no longer possible to create a short circuit through the oscilloscope or through a second device connected to your computer and to the car, like e.g. a fault code scanner. So no risk of damaging the car, the oscilloscope or the computer.

Differential / single-ended switchable inputs with SafeGround protection

SafeGround

SafeGround gives the possibility to use the oscilloscope inputs both as single-ended and as differential. When SafeGround is active and you accidentally create a wrong connection that causes a short circuit, SafeGround will disconnect the ground of the input channel without damaging the oscilloscope or PC. You can therefore simply switch from a differential input to a single-ended input without worrying if anything will damage because of a short circuit current. The Automotive Test Scope ATS610004D-XMSG is the only automotive oscilloscope in the world with this unique SafeGround protection. And as you all know, a connection mistake is easily made, which will now have no more strange and financial consequences because of SafeGround as the short circuit current is limited thanks to SafeGround.

SafeGround is default available on each channel of the Automotive Test Scope ATS610004D-XMSG.

SureConnect

SafeGround

The SureConnect connection test feature of the Automotive Test Scope ATS610004D-XMSG tells you immediately whether your test probe or clip actually makes electrical contact or not. No more doubt whether your probe doesn’t make contact or there really is no signal.

This is useful when surfaces are oxidized and your probe cannot get a good electrical contact. Simply activate the SureConnect and you know whether there is contact or not. Also when back probing connectors in confined places, SureConnect immediately shows whether the probes make contact or not.

SureConnect is default available on each channel of the Automotive Test Scope ATS610004D-XMSG.

Resistance measurement

Potmeter testing

Many automotive sensors are based on variable resistors. Use your Automotive Test Scope ATS610004D-XMSG in the resistance setting to test them, no more need to take a separate ohm meter. Resistance values can be displayed as a number, but it is also possible to display the resistance variation in time, in a graph.

The unique Automotive Test Scope ATS610004D-XMSG Ohm scope is the first fast automotive Ohm scope in its class.

Large memory

Zoom in 1 million times

When measuring at high sample rates, a long record length/large memory is necessary to be able to record a complete signal in the acquisition buffer. Where most oscilloscopes have 2.5 kpoints or 100 kpoints memory, the Automotive Test Scope ATS610004D-XMSG has up to 256 Mpoints memory per channel, depending on the selected resolution and the number of active channels. When measuring at 14 bit resolution and all four channels, the available memory is 32 Mpoints per channel. This gives the user 300 to 100000 times more memory.

An advantage of a large memory is that once-only fast phenomena can be captured accurately or complete serial communication signal blocks can be measured all at once. For example complete serial communications, like CAN bus signals, can be measured all in one record to be reviewed and analyzed afterwards.

High accuracy

Zoomed in to 8 mV range

The Automotive Test Scope ATS610004D-XMSG measures with high resolutions of 14 and 16 bit. A signal measured with the Automotive Test Scope ATS610004D-XMSG therefore has 256 times more resolution than most standard automotive oscilloscopes, which usually have a low resolution of 8 or 9 bit. The input circuit of the Automotive Test Scope ATS610004D-XMSG has a high accuracy of 0.25 % of the full scale input range, where most standard automotive oscilloscopes have an accuracy of 2 – 3 % of the full scale range. The precision Automotive Test Scope ATS610004D-XMSG allows for measuring signals with much more accuracy.

 

Specifications

Acquisition system

Number of input channels 4 analog
CH1, CH2, CH3, CH4 Isolated BNC, female
Type Differential input
Resolution User selectable in software
Native 8, 12, 14 bit
Enhanced 16 bit
DC Accuracy 0.25 % (0.1 % typical) of full scale ± 1 LSB at 20°C to 25°C
To achieve rated accuracy, allow the instrument to settle for 20 minutes. When subjected to extreme temperatures, allow additional time for internal temperatures to stabilize.
Noise 305 µVrms (200 mV range, 12 bit, 50 MSa/s)
90 µVrms (200 mV range, 16 bit, 6.25 MSa/s)
Ranges (full scale) ±200 mV
±400 mV
±800 mV
±2 V
±4 V
±8 V
±20 V
±40 V
±80 V
Coupling AC/DC
Impedance 2 MOhm / 12 pF ± 1 %
1 MOhm / 20 pF ± 1 % when SafeGround enabled
Maximum voltage 200 V (DC + AC peak < 10 kHz)
Maximum Common Mode voltage 200 mV to 800 mV ranges 2 V
2 V to 8 V ranges : 20 V
20 V to 80 V ranges : 200 V
Common Mode Rejection Ratio -47 dB
Bandwidth
-3dB at 75 % of full scale input 250 MHz
Limit, selectable per channel Off (250 MHz), 150 MHz, 100 MHz, 50 MHz
AC coupling cut off frequency (-3dB) ±1.5 Hz
SureConnect
Maximum voltage on connection 200 V (DC + AC peak < 10 kHz)
Resistance measurement
Ranges 100 Ω
200 Ω
500 Ω
1 kΩ
2 kΩ
5 kΩ
10 kΩ
20 kΩ
50 kΩ
100 kΩ
200 kΩ
500 kΩ
1 MΩ
2 MΩ
Accuracy 1 % of full scale
Response time (to 95%) < 10 µs
SafeGround
Maximum voltage on connection 200 V (DC + AC peak < 10 kHz)
Maximum switch off current 500 mA
Response time < 100 ns
Maximum sampling rate 8 bit 12 bit 14 bit 16 bit
measuring one channel 1 GSa/s 500 MSa/s 100 MSa/s 6.25 MSa/s
measuring two channels 500 MSa/s 200 MSa/s 100 MSa/s 6.25 MSa/s
measuring three or four channels 200 MSa/s 100 MSa/s 100 MSa/s 6.25 MSa/s
Maximum streaming rate 1 8 bit 12 bit 14 bit 16 bit
measuring one channel 200 MSa/s 2 100 MSa/s 3 100 MSa/s 3 6.25 MSa/s 6
measuring two channels 100 MSa/s 3 50 MSa/s 4 50 MSa/s 4 6.25 MSa/s 6
measuring three or four channels 50 MSa/s 4 25 MSa/s 5 25 MSa/s 5 6.25 MSa/s 6
  1. On some computers, the highest streaming rates may not be available, due to computer restrictions.
  2. ≤ 40 MSa/s when connected to USB 2.0
  3. ≤ 20 MSa/s when connected to USB 2.0
  4. ≤ 10 MSa/s when connected to USB 2.0
  5. ≤ 5 MSa/s when connected to USB 2.0
  6. ≤ 3.125 MSa/s when connected to USB 2.0
Sampling clock source
Internal TCXO
Accuracy ± 0.0001 %
Stability ± 1 ppm over 0°C to 55°C
Time base aging ±1 ppm/year
External LVDS, on CMI connectors
Input range 10 MHz ± 1 %
16.369 MHz ± 1 %
Memory 8 bit 12, 14, 16 bit
Measuring one channel 256 Mpoints per channel 128 Mpoints per channel
Measuring two channels 128 Mpoints per channel 64 Mpoints per channel
Measuring three or four channels 64 Mpoints per channel 32 Mpoints per channel
Trigger Only available in scope/block mode, not in streaming mode
System Digital, 2 levels
Source CH1, CH2, CH3, CH4, OR, digital external
Trigger modes Rising edge, Falling edge, Any edge
Inside window, Outside window, Enter window, Exit window (time conditions only on Ch1)
Pulse width (only on Ch1)
Interval (only on Ch1)
Level adjustment 0 to 100 % of full scale
Hysteresis adjustment 0 to 100 % of full scale
Resolution 0.006 % (14, 16 bits) / 0.025% (12 bits)
Pre trigger 0 to selected record length, 1 sample resolution
Post trigger 0 to selected record length, 1 sample resolution
Trigger hold-off 0 to 63 MSamples, 1 sample resolution
Trigger delay 0 to 8 GSamples, 1 sample resolution
Digital external trigger
Input Extension connector pins 1 and 2
Range 0 to 2.5 V (TTL)
Coupling DC
Jitter ≤ 1 sample

Multi-instrument synchronization

Using CMI Synchronizing instruments via CMI is available when all instruments are connected via USB.
Maximum number of instruments Limited by number of available USB ports
Synchronization accuracy 0 ppm
CMI interface 2x, CMI 1, CMI 2
Required coupling cable TP-C50H CMI Coupling cable
Maximum coupling cable length 50 cm
Using WCMI Synchronizing instruments via WCMI is available when instruments are connected via USB, LAN and WiFi.
Maximum number of instruments No limitation
Required coupling module WCMI – 8, WCMI – 9
Clock synchronization accuracy ≤ 1 ppm, typical ≤ 0.2 ppm
Trigger jitter at sample rate 1 ≤ 1 MSa/s > 1 MSa/s
2 x “5” ≤ ±2 samples ≤ ±2 µs
“5” and “6”
Trigger source “5” ≤ ±2 samples ≤ ±2 µs
Trigger source “6” ≤ ±8 samples ≤ ±8 µs
2 x “6” ≤ ±8 samples ≤ ±8 µs
  1. “5” = WiFiScope WS5 or Handyscope HS5.
    “6” = WiFiScope WS6 DIFF, WiFiScope WS6, Handyscope HS6 DIFF, Handyscope HS6, ATS610004DW-XMSG, ATS610004D-XMSG, ATS605004DW-XMS or ATS605004D-XMS

Probe calibration

Output Extension connector pins 3 (signal) and 6 (ground)
Signal Square wave
Level -1 V to 1 V
Frequency 1 kHz

Interface

Interface USB 3.0 SuperSpeed (5 Gbit/s);
(USB 2.0 HighSpeed compatible)

Power Requirements

Power From USB port or external input
Consumption 5 VDC 1200 mA max
External power From second USB port or power adapter

Physical

Instrument
Height 25 mm (1 inch)
Length 170 mm (6.7 inch)
Width 140 mm (5.2 inch)
Weight 500 g (17.6 ounce)
USB cord length 1.8 m (70 inch)

I/O connectors

Channel 1, 2, 3, 4 Isolated BNC, female
USB Fixed cable with USB 3.0 type A connector, 1.8 m
Extension connector D-sub 9 pins female
Power 3.5 mm power socket
CMI I/O connectors 2 x HDMI type C socket

System requirements

PC I/O connection USB 2.0, USB 3.0 or USB 3.1
Operating system Windows 10 / 11, 64 bits
Linux (via own software based on libtiepie-hw SDK)

Environmental conditions

Operating
Ambient temperature 20°C to 25°C (10°C to 40°C without specifications)
Relative humidity 10 % to 90 %, non condensing
Storage
Ambient temperature -20°C to 70°C
Relative humidity 5 % to 95 %, non condensing

Certifications and Compliances

CE mark compliance Yes
RoHS Yes
EN 55011:2009/A1:2010 Yes
EN 55022:2006/A1:2007 Yes
EN 61000-6-1:2007 Yes
EN 61000-6-3:2007 Yes

Package contents

Instrument Automotive Test Scope ATS610004D-XMSG
Measure leads 4 x Measure lead TP-C1812B, Differential BNC -> 4 mm banana plug
Differential attenuator 4 x Differential attenuator TP-DA10
Accessories Handyscope power supply, external power cable for USB port, Probe compensation cable TP-DB9-BNC-30
Software for Windows 10 / 11, 64 bits, via website
Drivers for Windows 10 / 11, 64 bits, via website
Manuals instrument manual and software user’s manuals
color printed and digital, via website

Customer service

TiePie engineering instruments are designed, manufactured and tested to provide high reliability. In the unlikely event you experience difficulties, the TiePie engineering instruments are fully warranted for two years.
This warranty includes All parts and labor (excluding probes and/or measure leads)
No charge for return shipping
Long-term 7 year support
Upgrade to the latest software at no charge

 

Package contents

The Automotive Test Scope ATS610004D-XMSG is delivered with:

Carry case Carry case BB391
Instrument Automotive Test Scope ATS610004D-XMSG
Measure leads 4 x Measure lead TP-C1812B, Differential BNC -> 4 mm banana plug
Differential attenuator 4 x Differential attenuator TP-DA10
Alligator clips, large Alligator Clip TP-AC80I – Set of 8: Green, Blue, Yellow, Red, 4 Black, 8 large alligator clips
Alligator clips, medium Alligator Clip TP-AC10I – Set of 8: Green, Blue, Yellow, Red, 4 Black, 8 medium alligator clips
Alligator clips, small Alligator Clip TP-AC5 – Set of 8: Green, Blue, Yellow, Red, 4 Black, 8 small alligator clips
Accessories Handyscope power supply, external power cable for USB port, Probe compensation cable TP-DB9-BNC-30
Software for Windows 10 / 11, 64 bits, via website
Drivers for Windows 10 / 11, 64 bits, via website
Manuals instrument manual and software user’s manuals
color printed and digital, via website

 

Downloads

Several downloads for the Automotive Test Scope ATS610004D-XMSG are listed below, including Multi Channel oscilloscope software,
drivers and manuals.

Driver & Software

Description Version Remarks Size
WinUSB driver 10.0.2 Windows 10 / 11, 64 bit 1.73 MB download
Multi Channel software 1.48.0 Windows 10 / 11, 64 bit, including PDF manual 104.80 MB download

Manuals & Documents

Description Version Remarks Size
Multi Channel software manual 1.11 English 3.13 MB download
Automotive Test Scope ATS610004D-XMSG Instrument manual 2.55 English 975.63 kB download